Material Analysis
10 Aufrufe
Hydrolytic Aging of CMC
Problembeschreibung
Mechanical properties of CMC products decrease by >25% in hot and humid environment
Ursachenanalyse
CMC contains polar groups that hydrolyze and break chains under hot and humid conditions; ester bonds/amide bonds etc. are sensitive to water
Lösung
1)Select low-polarity content grade to reduce hydrolysis tendency; 2)Add anti-hydrolysis stabilizer; 3)Coat the product surface with a waterproof layer
Wichtigste Erkenntnis
Hydrolytic aging is caused by polar groups being sensitive to water; selecting a low-polarity grade is the key
War das hilfreich?
0 Personen fanden dies hilfreich
Vielen Dank für Ihr Feedback!