Material Analysis 14 visualizações

Hydrolytic Aging of CMC

Fenómeno do problema
Mechanical properties of CMC products decrease by >25% in hot and humid environment
Análise das causas
CMC contains polar groups that hydrolyze and break chains under hot and humid conditions; ester bonds/amide bonds etc. are sensitive to water
Solução
1)Select low-polarity content grade to reduce hydrolysis tendency; 2)Add anti-hydrolysis stabilizer; 3)Coat the product surface with a waterproof layer
Conclusão principal
Hydrolytic aging is caused by polar groups being sensitive to water; selecting a low-polarity grade is the key