Injection Molding
2 Aufrufe
Glass Fibre '2079851475616104452 flow marks
Problembeschreibung
Glass Fibre injection molded product surface shows radial flow marks centered on gate
Ursachenanalyse
Injection speed too fast causes melt front instability; mold temperature too low <30°C, front rapidly cools forming marks
Lösung
1) Adopt multi-stage injection speed slow-fast-slow to control front stability; 2) raise mold temperature to 40-50°C to delay front cooling; 3) stabilize injection pressure to avoid fluctuation; 4) enlarge gate area to reduce pressure sudden change at gate
Wichtigste Erkenntnis
Flow marks are caused by injection front instability and rapid cooling; multi-stage injection and high mold temperature are key
War das hilfreich?
0 Personen fanden dies hilfreich
Vielen Dank für Ihr Feedback!