Injection Molding
4 Aufrufe
MP '2079851475616104452 flow marks
Problembeschreibung
MP injection molded product surface shows radial flow marks centered on the gate
Ursachenanalyse
injection speed too fast causing unstable melt front; mold temperature too low <30°C, front rapidly cools forming marks
Lösung
1) adopt multi-stage injection speed slow-fast-slow to control front stability; 2) raise mold temperature to 40-50°C to delay front cooling; 3) stabilize injection pressure to avoid fluctuation; 4) enlarge gate area to reduce pressure sudden change at the gate
Wichtigste Erkenntnis
flow marks are caused by unstable injection front and rapid cooling; multi-stage injection and high mold temperature are key
War das hilfreich?
0 Personen fanden dies hilfreich
Vielen Dank für Ihr Feedback!