Material Analysis
3 Aufrufe
LCP product regrind performance degradation
Problembeschreibung
Performance decreases significantly when LCP scrap is recycled and reused.
Ursachenanalyse
With each heat history (>370°C) of LCP, molecular chains break and molecular weight decreases.
Lösung
Control regrind ratio ≤20%; control recycling pelletizing temperature.
Wichtigste Erkenntnis
Quality degradation of LCP recycled material requires ratio management.