LCP product regrind performance degradation

Problem Phenomenon
Performance decreases significantly when LCP scrap is recycled and reused.
Cause Analysis
With each heat history (>370°C) of LCP, molecular chains break and molecular weight decreases.
Solution
Control regrind ratio ≤20%; control recycling pelletizing temperature.
Key Takeaway
Quality degradation of LCP recycled material requires ratio management.