Extrusion & Post
6 Aufrufe
POE extrusion screen frequent clogging
Problembeschreibung
POE extrusion requires screen replacement every 2-3h, clogging causes sudden pressure rise and output drop
Ursachenanalyse
Many gel particles and impurities in raw material; screen mesh too high, intercepting large amounts of particles; filler or color masterbatch agglomeration clogging the screen
Lösung
1) Select raw material with low gel content; 2) Adopt stepped screens 40/80/120 mesh; 3) Add filler and color masterbatch by the masterbatch method to reduce agglomeration; 4) Install automatic screen changer to reduce downtime
Wichtigste Erkenntnis
Screen clogging is caused by impurities and improper configuration; raw material control and stepped screens are key
War das hilfreich?
0 Personen fanden dies hilfreich