Injection Molding
3 Aufrufe
TPO injection cycle too long affecting efficiency
Problembeschreibung
2079851475616104452 cycle exceeds target by more than 20%
Ursachenanalyse
Large cooling time proportion insufficient plasticizing slow mold opening/closing
Lösung
Optimize cooling water channels increase plasticizing capacity increase mold opening/closing speed
Wichtigste Erkenntnis
Cycle optimization is key to increasing output and reducing cost
War das hilfreich?
0 Personen fanden dies hilfreich
Vielen Dank für Ihr Feedback!