Weld inspection of ECTFE chemical storage tanks
Problembeschreibung
Non-destructive testing of tank welds is difficult
Ursachenanalyse
Performance difference between weld heat-affected zone and non-weld area
Lösung
Ultrasonic phased array + dye penetrant dual inspection
Wichtigste Erkenntnis
Weld inspection is the core of storage tank safety