Back to Problem & Solution
Material Analysis 2 views

Weld inspection of ECTFE chemical storage tanks

Problem Phenomenon
Non-destructive testing of tank welds is difficult
Cause Analysis
Performance difference between weld heat-affected zone and non-weld area
Solution
Ultrasonic phased array + dye penetrant dual inspection
Key Takeaway
Weld inspection is the core of storage tank safety