Processing Machinery
5 Aufrufe
ETFE produces corrosive gas at high temperature
Problembeschreibung
Irritating odor around equipment when processing ETFE
Ursachenanalyse
At processing temperature 300-330°C, ETFE slightly decomposes to produce hydrogen fluoride (HF); residence time too long
Lösung
Strictly control temperature ≤330°C; shorten residence time; strengthen ventilation and waste gas treatment
Wichtigste Erkenntnis
Fluoropolymers at high processing temperatures need attention to HF release
War das hilfreich?
0 Personen fanden dies hilfreich