Processing Machinery
9 visualizações
ETFE produces corrosive gas at high temperature
Fenómeno do problema
Irritating odor around equipment when processing ETFE
Análise das causas
At processing temperature 300-330°C, ETFE slightly decomposes to produce hydrogen fluoride (HF); residence time too long
Solução
Strictly control temperature ≤330°C; shorten residence time; strengthen ventilation and waste gas treatment
Conclusão principal
Fluoropolymers at high processing temperatures need attention to HF release
Isto foi útil?
0 pessoas acharam isto útil