Processing Machinery
5 Aufrufe
PVDF high-temperature processing produces hydrogen fluoride
Problembeschreibung
Pungent gas is generated during processing and equipment is corroded
Ursachenanalyse
Above 260C, PVDF eliminates HF
Lösung
Strictly control below 260°C and ventilate
Wichtigste Erkenntnis
HF is harmful to people and equipment
War das hilfreich?
0 Personen fanden dies hilfreich