Processing Machinery
4 views
PVDF high-temperature processing produces hydrogen fluoride
Problem Phenomenon
Pungent gas is generated during processing and equipment is corroded
Cause Analysis
Above 260C, PVDF eliminates HF
Solution
Strictly control below 260°C and ventilate
Key Takeaway
HF is harmful to people and equipment
Was this helpful?
0 people found this helpful