Injection Molding
10 Aufrufe
Stress Concentration in the Gate Area of PBT Injection-Molded Parts
Problembeschreibung
The stress in the gate area of the product is high, which is obvious under polarized light.
Ursachenanalyse
The temperature gradient and flow history of the gate area are different; the molecular chain orientation in this area is high, the cooling is fast, and the internal stress is large.
Lösung
Use a larger gate to reduce the shear and orientation in this area; increase the mold temperature in this area; anneal.
Wichtigste Erkenntnis
The PBT gate area is an internal stress concentration area.
War das hilfreich?
0 Personen fanden dies hilfreich