Molds & Tooling
3 Aufrufe
PAI mold temperature control requirements
Problembeschreibung
The mold temperature must be maintained above 200°C
Ursachenanalyse
PAI requires extremely high mold temperature to achieve flow and initial curing
Lösung
Use an oil temperature controller (up to 250°C); add insulation plates to the mold
Wichtigste Erkenntnis
PAI '2079851475616104452 has extreme requirements for mold temperature control
War das hilfreich?
0 Personen fanden dies hilfreich