Material Analysis 6 visualizaciones

ASA Weather Resistance Test Verification

Fenómeno del problema
【Problem Phenomenon】ASA supplier claims weather resistance, lacking quantitative verification means
Análisis de la causa
Weather resistance must be verified according to standards: ASTM G155/ISO 4892 xenon lamp aging, Delta E<3 is a typical requirement; gloss retention, chalking rating, impact retention are assessed simultaneously
Solución
Do 1000-5000h aging verification according to ASTM G155; Delta E, gloss, chalking, impact four indicators for acceptance; supplier data reviewed on-site
Conclusión clave
ASA weather resistance looks at Delta E<3 four indicators, claims are inferior to verification; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
weather resistance test xenon lamp Delta E chalking