Menú
Materiales Maquinaria
Perspectivas
Artículos Vídeos Problema y solución
About
Acerca de Chembull Socios de medios
Contáctenos
Idioma
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Volver a Problema y solución
Material Analysis 6 visualizaciones

Utilization of LCP Orientation-Direction Mechanical Property Differences

Fenómeno del problema
【Problem Phenomenon】The longitudinal tensile strength of the same LCP specimen can be about 3 times the transverse, and the dispersion of test data causes misjudgment
Análisis de la causa
LCP molecular chain flow orientation makes longitudinal strength significantly higher than transverse; test values differ greatly with different sampling directions; the MEMS textbook records that longitudinal strength can be 3 times the transverse
Solución
Mark the direction in test sampling and unify the orientation benchmark; in design, arrange the flow direction according to the stress direction to utilize the high longitudinal strength; for verification, conservatively take the low transverse value; after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability
Conclusión clave
LCP performance data must carry direction; design verification uses the conservative transverse value; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for subsequent similar problems
orientation mechanical properties directionality test sampling

¿Le ha resultado útil?

0 personas encontraron esto útil

ChemAI