Processing Machinery
7 visualizaciones
LLDPE gel particles
Fenómeno del problema
Complaints about gel particles in LLDPE film
Análisis de la causa
Oxidized gel or unmelted particles mixed in; when troubleshooting on site, verify item by item according to this mechanism to avoid blindly adjusting the machine based only on experience; this mechanism has been repeatedly verified by industry data and should be confirmed first during troubleshooting
Solución
Residence management; finer filter screen; raw material cleanliness; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability; change only one variable at a time and record parameter changes to facilitate locating effective measures
Conclusión clave
Gel relies on residence management and filtration; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a reference for troubleshooting similar problems in the future
¿Le ha resultado útil?
0 personas encontraron esto útil
¡Gracias por sus comentarios!