Menú
Materiales Maquinaria
Perspectivas
Artículos Vídeos Problema y solución
About
Acerca de Chembull Socios de medios
Contáctenos
Idioma
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Volver a Problema y solución
Processing Machinery 7 visualizaciones

PC/ABS color matching color difference

Fenómeno del problema
Color deviates from the standard sample.
Análisis de la causa
Color masterbatch compatibility or metering problem; temperature affects color development.; during on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based on experience alone; this mechanism has been repeatedly verified by industry data and should be confirmed first during troubleshooting
Solución
①Select compatible color masterbatch; ②stabilize metering; ③control temperature; ④test by batch.; after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability; change only one variable at a time and record the parameter changes, to facilitate locating the effective measures
Conclusión clave
Color difference relies on color masterbatch and temperature control management.; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for similar problems later
PC/ABS;color difference;color masterbatch;metering;temperature;test

¿Le ha resultado útil?

0 personas encontraron esto útil

ChemAI