Processing Machinery 7 visualizaciones

Inspection Standards for PLA Products

Fenómeno del problema
Disagreements in quality judgment.
Análisis de la causa
PLA test standards differ from those of traditional materials; biodegradation testing is even more special.; During on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based solely on experience
Solución
①Clarify test standards; ②Agree on conditions and methods; ③Both sides benchmark; ④Standard samples.; After adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability
Conclusión clave
The PLA standard system must be specifically agreed upon.; After confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a reference for troubleshooting similar problems in the future