Processing Machinery 7 visualizaciones

PVB Assembly Environment

Fenómeno del problema
PVB assembly environment cleanliness is insufficient, dust and impurities are trapped, optical defects.
Análisis de la causa
PVB assembly needs a clean environment; dust and impurities; static electricity adsorption; personnel operation; environmental monitoring.; When troubleshooting on site, verify item by item according to this mechanism, avoiding blind machine adjustment based only on experience
Solución
①Cleanroom environment control; ②Static electricity elimination; ③Operation specification training; ④Environmental monitoring records.; After adjustment, continuously sample to verify the effect, confirm stability before resuming mass production
Conclusión clave
PVB assembly cleanliness is optical quality assurance; static electricity management is a detail; specification execution prevents contamination.; After confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence