Injection Molding 3 visualizaciones

PVC Injection Product Dimension Instability

Fenómeno del problema
Dimensions fluctuate, poor assembly.
Análisis de la causa
Uneven plasticization, cushion fluctuation, mold temperature drift; PVC plasticization fluctuation directly transmits to dimension fluctuation; during on-site troubleshooting, verify item by item according to this mechanism, avoid blindly adjusting the machine based solely on experience.
Solución
①Stabilize plasticization; ②Continuously monitor cushion fluctuation as early warning of metering stability; ③Mold temperature machine constant-temperature water supply to avoid quality fluctuation caused by mold temperature drift; ④Stabilize regrind proportion; ⑤Establish SPC process monitoring to detect dimension drift in time.
Conclusión clave
PVC dimension = 'plasticization and metering stability': plasticization fluctuation is PVC's characteristic root of dimension instability; stabilize plasticization and metering, dimensions are then guaranteed; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence.
PVC; '2079851475616104452; dimension; plasticization; cushion

¿Le ha resultado útil?

0 personas encontraron esto útil