Material Analysis
15 visualizaciones
CEF tensile strength insufficient
Fenómeno del problema
The tensile strength of the CEF product is 15-20% lower than the standard value
Análisis de la causa
The CEF molecular weight is low and the strength foundation is insufficient; the filler interface is poor and does not play a reinforcing role; the orientation is excessive, strong in the longitudinal direction and weak in the transverse direction
Solución
1) Select high-molecular-weight CEF grades; 2) Treat the filler with a coupling agent to improve the interface; 3) Reduce the orientation to reduce the longitudinal-transverse difference
Conclusión clave
Insufficient tensile strength is caused by molecular weight and poor interface; selecting high MW grades is the key
¿Le ha resultado útil?
0 personas encontraron esto útil
¡Gracias por sus comentarios!