Material Drying
8 visualizaciones
Control of strength abnormality in PEOX coating medical products
Fenómeno del problema
During PEOX coating production of medical products, the problem of large fluctuation in strength occurs.
Análisis de la causa
Mainly due to the processing temperature deviating from the window +65-95°C, moisture content >0.3% exceeding the standard, and excessively long residence time.
Solución
Strictly control the temperature within the recommended range, fully dry the material to moisture content <0.1%, and shorten the residence time.
Conclusión clave
PEOX processing requires precise control of the three elements of temperature, humidity, and residence time.
¿Le ha resultado útil?
0 personas encontraron esto útil