Material Drying
8 visualizaciones
Control of winding abnormality in PEOX coating medical products
Fenómeno del problema
During PEOX coating production of medical products, the problem of not up to standard winding occurs.
Análisis de la causa
Mainly due to the processing temperature deviating from the window +65-95°C, moisture content >0.5% exceeding the standard, and insufficient cooling.
Solución
Strictly control the temperature within the recommended range, fully dry the material to moisture content <0.1%, and reduce the screw speed.
Conclusión clave
PEOX processing requires precise control of the three elements of temperature, humidity, and residence time.
¿Le ha resultado útil?
0 personas encontraron esto útil