Injection Molding 7 visualizaciones

Unstable pressure of the hydraulic system of PETG '2079851475616104452

Fenómeno del problema
The pressure fluctuates greatly in each stage of '2079851475616104452, and mold filling and holding are unstable.
Análisis de la causa
Hydraulic pump or proportional valve failure, oil contamination or oil temperature too high, and system leakage.
Solución
Check and maintain the hydraulic pump and valves; replace the hydraulic oil to keep it clean; control the system oil temperature.
Conclusión clave
PETG injection pressure stability depends on the health of the hydraulic system.