Material Analysis 8 visualizaciones

Flame retardant grade of modified methyl methacrylate-butadiene-styrene copolymer not up to standard

Fenómeno del problema
Flame retardant grade of modified methyl methacrylate-butadiene-styrene copolymer is not up to standard; vertical burning or horizontal burning tests fail to pass the target grade
Análisis de la causa
Insufficient flame retardant addition amount Poor compatibility between flame retardant and methyl methacrylate-butadiene-styrene copolymer, uneven dispersion Flame retardant decomposes and fails at processing temperature Improper flame retardant system design Processing temperature too high, flame retardant degrades
Solución
Increase flame retardant addition amount Select flame retardants with good compatibility Select flame retardants stable within the processing temperature range Optimize flame retardant system design Control processing temperature to avoid flame retardant degradation
Conclusión clave
Flame retardancy needs to start from addition amount, compatibility, and system design