Material Drying
3 조회수
PA66 rapid moisture content detection
문제 현상
No Karl Fischer instrument on site, unable to judge whether PA66 drying is qualified
원인 분석
When moisture content judgment lacks means, one can only rely on experience, drying quality loss-of-control risk is high, batch differences cannot be quantified; during on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based solely on experience
해결 방법
Equip a rapid moisture analyzer for on-site screening, regularly compare and calibrate with the Karl Fischer method; air-shot strands can also be observed for bubbles as qualitative judgment; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
핵심 요약
On-site rapid screening plus laboratory arbitration two-level detection is a practical solution; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for subsequent similar problems
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!