Material Drying
6 مشاهدة
PA66 rapid moisture content detection
ظاهرة المشكلة
No Karl Fischer instrument on site, unable to judge whether PA66 drying is qualified
تحليل الأسباب
When moisture content judgment lacks means, one can only rely on experience, drying quality loss-of-control risk is high, batch differences cannot be quantified; during on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based solely on experience
الحل
Equip a rapid moisture analyzer for on-site screening, regularly compare and calibrate with the Karl Fischer method; air-shot strands can also be observed for bubbles as qualitative judgment; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
الخلاصة الأساسية
On-site rapid screening plus laboratory arbitration two-level detection is a practical solution; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for subsequent similar problems
هل كان هذا مفيدًا؟
0 شخص وجدوا هذا مفيدًا
شكرًا لك على ملاحظاتك!