Injection Molding 6 조회수

PARA Mold Heat Insulation

문제 현상
Heat transfer between the PARA high-temperature mold and the injection machine platen; temperature loss and equipment heat damage.
원인 분석
PARA mold temperature of 120~140°C requires heat insulation; use insulation plates between the mold and the machine platen; heat transfer affects mold temperature stability; equipment thermal management.
해결 방법
①Use insulation plates between the mold and the machine platen; ②Match mold temperature controller capacity; ③Monitor mold temperature stability; ④Verify insulation effect.; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
핵심 요약
Insulation plates for PARA high-temperature molds are standard configuration; mold temperature stability depends on thermal management; equipment protection is considered in parallel.; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
PARA; mold; insulation plate; mold temperature; thermal management; equipment