Injection Molding
7 görüntüleme
PARA Mold Heat Insulation
Sorun Belirtisi
Heat transfer between the PARA high-temperature mold and the injection machine platen; temperature loss and equipment heat damage.
Neden Analizi
PARA mold temperature of 120~140°C requires heat insulation; use insulation plates between the mold and the machine platen; heat transfer affects mold temperature stability; equipment thermal management.
Çözüm
①Use insulation plates between the mold and the machine platen; ②Match mold temperature controller capacity; ③Monitor mold temperature stability; ④Verify insulation effect.; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Temel Çıkarım
Insulation plates for PARA high-temperature molds are standard configuration; mold temperature stability depends on thermal management; equipment protection is considered in parallel.; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
Bu faydalı oldu mu?
0 kişi bunu faydalı buldu
Geri bildiriminiz için teşekkürler!