메뉴
재료 기계
인사이트
기사 동영상 문제 및 해결책
About
Chembull 소개 미디어 파트너
문의하기
언어
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
문제 및 해결책으로 돌아가기
Molding Process 6 조회수

PET melt pump pressure stabilization

문제 현상
Sinusoidal periodic fluctuations appear in sheet thickness, which the automatic thickness measurement system cannot completely eliminate
원인 분석
Slight fluctuations in melt pump speed appear as sinusoidal thickness bands; wear of the pump drive coupling introduces torsional oscillation; the closed-loop thickness measurement system can track it but cannot remove the upstream disturbance
해결 방법
① Check the melt pump drive coupling for wear; ② control pump speed fluctuation within 0.5%; ③ independently zone-heat the die bolts to control expansion; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
핵심 요약
The melt pump is the heart of PET sheet thickness stability; upstream fluctuations must be eliminated at the source, and downstream closed-loop is only a remedy; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
PET;melt pump;thickness fluctuation;coupling;pressure stabilization

이 정보가 도움이 되었나요?

0 명이 도움이 되었다고 합니다

ChemAI