Molds & Tooling
4 조회수
PSU Wall Thickness Design Constraints
문제 현상
PSU products designed with too thin wall thickness cause filling difficulty and insufficient strength; mold scrap losses after design changes are large.
원인 분석
PSU melt has poor flowability; the ratio of melt flow length to wall thickness is only about 80; product wall thickness must not be less than 1.5mm, mostly above 2mm; thin-wall design is inherently infeasible.
해결 방법
①In the design stage, wall thickness not less than 1.5mm, recommended above 2mm; ②Check the flow length ratio at 80; ③For thin-wall requirements, switch to high-flow grades or materials; ④Material review before mold design.
핵심 요약
PSU wall thickness constraints are hard boundaries determined by material flowability; the 1.5mm bottom line cannot be broken; advancing design review avoids mold waste.; After confirming effectiveness, solidify the parameters and practices into the work instructions to prevent recurrence
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!