Extrusion & Post
11 조회수
PVC Extrusion Pipe Temperature
문제 현상
Extruded PVC pipe inner wall rough, surface sharkskin, or degraded yellow lines
원인 분석
Improper extrusion temperature zoning: feed zone 60-80℃ preheating, compression zone 140-150℃ plasticizing, metering zone 160-170℃ homogenizing, die head 170-180℃ shaping; local overheating immediately gives yellow lines
해결 방법
①Set and stabilize according to zoned temperature curve; ②Uniform die head temperature to prevent yellow lines; ③Screw speed matched with haul-off; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
핵심 요약
PVC pipe extrusion is the art of zoned temperature control; each zone has its duty, local overheating immediately shows; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!