PVC Thermocouple Calibration

문제 현상
Multiple PVC machines producing with same parameters, degradation degree differs
원인 분석
Thermocouple deviation makes actual temperatures differ, PVC narrow window extremely sensitive to deviation; during on-site troubleshooting, verify item by item according to this mechanism, avoid blindly adjusting the machine based solely on experience.
해결 방법
Thermocouples regularly calibrated; replace when deviation exceeds ±2℃; process parameters unified by actual measured temperature; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
핵심 요약
PVC temperature control metering managed at ±2℃ precision; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for similar problems later
PVC thermocouple calibration precision