Menú
Materiales Maquinaria
Perspectivas
Artículos Vídeos Problema y solución
About
Acerca de Chembull Socios de medios
Contáctenos
Idioma
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Volver a Problema y solución
Processing Machinery 7 visualizaciones

PVC Thermocouple Calibration

Fenómeno del problema
Multiple PVC machines producing with same parameters, degradation degree differs
Análisis de la causa
Thermocouple deviation makes actual temperatures differ, PVC narrow window extremely sensitive to deviation; during on-site troubleshooting, verify item by item according to this mechanism, avoid blindly adjusting the machine based solely on experience.
Solución
Thermocouples regularly calibrated; replace when deviation exceeds ±2℃; process parameters unified by actual measured temperature; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Conclusión clave
PVC temperature control metering managed at ±2℃ precision; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for similar problems later
PVC thermocouple calibration precision

¿Le ha resultado útil?

0 personas encontraron esto útil

ChemAI