Molds & Tooling
4 조회수
Cold slug marks appear on the product surface
문제 현상
Cold slug marks appear on the product surface, local poor gloss or hard lumps, usually near the gate
원인 분석
Nozzle temperature too low, producing cold slug
Front zone barrel temperature set low
Mold sprue or runner temperature low, cold slug retained
Mold opening gap too large, cold slug pulled into the cavity
Screw pullback distance too large, producing cold slug
해결 방법
Increase nozzle temperature to prevent cold slug
Appropriately increase the front zone barrel temperature
Increase sprue and runner dimensions to reduce cold slug retention
Reduce the mold opening gap
Adjust the screw pullback distance
핵심 요약
Cold slug marks require increasing nozzle temperature and reducing cold slug sources
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!