Extrusion & Post
10 조회수
DSTDP extruder screw severe wear
문제 현상
After 200h of DSTDP extrusion, screw and barrel wear reaches 0.5mm
원인 분석
Filler wears the screw greatly; screw material hardness insufficient, not nitrided; processing temperature on the high side causes DSTDP to adhere to the screw aggravating wear
해결 방법
1) Use nitrided screw or bimetallic screw SK-2 alloy; 2) lower processing temperature to reduce adhesive wear; 3) treat filler with coupling agent to reduce friction; 4) regularly check wear, replace in time when >0.3mm
핵심 요약
Screw wear is caused by filler friction and adhesion; wear-resistant screw and temperature control are key
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!