Injection Molding
5 조회수
DSTDP injection multi-cavity unbalanced filling
문제 현상
DSTDP injection 8-cavity mold, filling amount difference between cavities ±15%, some cavities short shot, some flash
원인 분석
Unbalanced runner design, runner lengths and resistance of each cavity inconsistent; gate sizes of each cavity inconsistent
해결 방법
1) Adopt balanced runner design to ensure equal length and equal resistance of each cavity runner; 2) gate sizes of each cavity precisely consistent ±0.01mm; 3) reduce injection speed to reduce the influence of resistance differences; 4) use mold flow analysis software to optimize runner design
핵심 요약
Multi-cavity unbalanced filling is caused by runner design; balanced runner and mold flow analysis are key
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!