Injection Molding 1 visualizações

DSTDP injection multi-cavity unbalanced filling

Fenómeno do problema
DSTDP injection 8-cavity mold, filling amount difference between cavities ±15%, some cavities short shot, some flash
Análise das causas
Unbalanced runner design, runner lengths and resistance of each cavity inconsistent; gate sizes of each cavity inconsistent
Solução
1) Adopt balanced runner design to ensure equal length and equal resistance of each cavity runner; 2) gate sizes of each cavity precisely consistent ±0.01mm; 3) reduce injection speed to reduce the influence of resistance differences; 4) use mold flow analysis software to optimize runner design
Conclusão principal
Multi-cavity unbalanced filling is caused by runner design; balanced runner and mold flow analysis are key
DSTDP injectionmulti-cavity balancerunner designgate sizemold flow analysis