Molds & Tooling
4 조회수
MP poor fatigue resistance
문제 현상
MP product fatigue life <10⁴ cycles, below the 10⁵ cycles requirement
원인 분석
MP elastic recovery insufficient, plastic deformation accumulates each cycle; crosslinking degree low, fatigue crack propagates fast
해결 방법
1) increase crosslinking degree to improve recovery and reduce accumulated deformation; 2) select a high molecular weight grade to raise the fatigue threshold; 3) product design to reduce stress concentration
핵심 요약
poor fatigue resistance is caused by insufficient recovery and fast crack propagation; increasing crosslinking is key