MP poor fatigue resistance
ظاهرة المشكلة
MP product fatigue life <10⁴ cycles, below the 10⁵ cycles requirement
تحليل الأسباب
MP elastic recovery insufficient, plastic deformation accumulates each cycle; crosslinking degree low, fatigue crack propagates fast
الحل
1) increase crosslinking degree to improve recovery and reduce accumulated deformation; 2) select a high molecular weight grade to raise the fatigue threshold; 3) product design to reduce stress concentration
الخلاصة الأساسية
poor fatigue resistance is caused by insufficient recovery and fast crack propagation; increasing crosslinking is key