Molds & Tooling 2 views

ASA Multi-Cavity Imbalance

Problem Phenomenon
【Problem Phenomenon】ASA multi-cavity mold products of each cavity have large weight and dimension differences
Cause Analysis
Runner imbalance and temperature unevenness cause inconsistent filling and holding in each cavity; medium viscosity materials are sensitive to runner differences; during on-site troubleshooting, verify item by item according to this mechanism, avoid blindly adjusting the machine based only on experience
Solution
Runner balance correction; each cavity temperature homogenized; SPC statistics by cavity number to locate differences; after adjustment, continuously sample to verify the effect, and resume mass production after confirming stability; change only one variable at a time and record parameter changes to facilitate locating effective measures
Key Takeaway
ASA multi-cavity differences check runner balance, locate by cavity number SPC; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for subsequent similar problems
multi-cavity runner balance SPC weight