Extrusion & Post 1 views

LDPE Extrusion Temperature Fluctuation

Problem Phenomenon
The temperature controller fluctuates greatly, and product quality fluctuates accordingly.
Cause Analysis
Thermocouple failure, heater band aging, and detuned PID parameters; fluctuations in the cooling air/water circuits also interfere.
Solution
①Calibrate the thermocouple; ②Replace aged heater bands; ③PID tuning; ④Stabilize the cooling medium.
Key Takeaway
For temperature fluctuation, check the sensor and actuator first.
LDPE; extrusion; temperature fluctuation; thermocouple; PID