Menu
Materials Machinery
Insights
Articles Videos Problem & Solution
About
About Chembull Media Partners
Contact Us
Language
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Back to Problem & Solution
Extrusion & Post 8 views

PLA Lactic Acid Smoke Precipitation

Problem Phenomenon
There is sour-smelling smoke in the PLA extrusion workshop, and white substance condenses on the cooling roll and die head surfaces
Cause Analysis
PLA high-temperature degradation generates lactic acid monomer through intramolecular transesterification, forming lactic acid smoke; lactic acid vapor condenses and precipitates on equipment surfaces, contaminating products and corroding equipment
Solution
①Lower the processing temperature to reduce lactic acid generation; ②Strengthen workshop and die head exhaust; ③Regularly clean the condensate on cooling rolls and die head; after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability
Key Takeaway
Lactic acid smoke is a visual signal of PLA degradation; cooling, exhaust, and cleaning in a three-pronged approach protect personnel and products; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
PLA; lactic acid smoke; precipitation; exhaust; condensation

Was this helpful?

0 people found this helpful

ChemAI