Problem Phenomenon
Rigid PVC parts were dimensionally stable, but after switching to soft PVC the same mold produced seriously out-of-tolerance dimensions
Cause Analysis
Rigid PVC shrinks only 0.2-0.6% with stable dimensions; soft PVC shrinks 1.0-2.5% due to plasticizer; molds for the two types cannot be shared, and material switching must be recalculated
Solution
①Design mold shrinkage allowance separately by rigid/soft category; ②allow 1.0-2.5% margin for soft PVC; ③verify first-piece dimensions when switching categories; after adjustment, continuously sample to verify the effect, and resume mass production after confirming stability
Key Takeaway
PVC shrinkage differs fivefold between rigid and soft; mold design must determine the category first, then set the allowance; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
PVC;shrinkage rate;0.2-0.6%;1.0-2.5%;rigid and soft