Molds & Tooling 2 views

PVDF Temperature Window Differences Among Grades

Problem Phenomenon
【Problem phenomenon】After switching to a different Kynar grade, continuing the original process causes insufficient filling or degradation
Cause Analysis
Differences in melt index and copolymer modification among grades make recommended barrel temperatures vary from 170-220℃ to 220-250℃, with mold temperature uniformly 50-90℃; the Arkema processing guide gives segment temperature tables by grade, and mixing parameters causes problems
Solution
When changing grades, first check the official temperature table and reset segment by segment; flexible grades such as SuperFlex have overall lower temperatures; verify the first piece before fixing the process card; After adjustment, take consecutive samples to verify the effect, and resume mass production only after confirming stability
Key Takeaway
Temperature windows differ greatly among PVDF grades; check the official temperature table first when changing material; After confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence