SMMA Mold Temperature

Problem Phenomenon
SMMA mold temperature 15-50℃ range, low and high temperature influences.
Cause Analysis
SMMA mold temperature 15-50℃; low temperature affects surface quality and stress; high temperature affects cycle and mold sticking; uniformity influence; thick-wall part demand.; during on-site troubleshooting, verify item by item according to this mechanism, avoiding blind machine adjustment based solely on experience
Solution
①Control mold temperature 15-50℃; ②appropriately raise for thick-wall parts; ③uniformity management; ④balance cycle and quality.; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Key Takeaway
SMMA mold temperature 15-50℃ is a wide range but needs selection; thick-wall parts are high-temperature scenarios; balance is the optimization goal.; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence