Material Analysis 9 views

Insufficient pipe impact strength

Problem Phenomenon
Falling weight impact test fails
Cause Analysis
Low molecular weight, processing temperature too high, degradation
Solution
Select appropriate K value, lower processing temperature
Key Takeaway
Insufficient impact is the bottleneck of CPVC pipe